Prosthetic heart valves: Part 1 – Selection (2024)

Vol. 20,N° 1 - 26 May 2021

Prosthetic heart valves: Part 1 – Selection (1)

Dr. Roland R. Brandt ,FESC

Prosthetic heart valves: Part 1 – Selection (2)

Prof. Philippe Pibarot ,FESC

Valve replacement is increasingly performed and has dramatically improved the outcome in patients with valvular heart disease. Bioprosthetic valves are characterised by a favourable haemodynamic performance but are at risk for structural valve degeneration, necessitating reintervention. In contrast, all mechanical valves offer long-term durability but require lifelong anticoagulation with the associated risk of bleeding and thromboembolism. The choice of prosthetic valve type involves careful consideration of the risks and benefits of each type of prosthesis and should also include patient preference in a shared decision-making process. The age of the patient is a very important factor. The negative impact of significant prosthesis-patient mismatch is an argument for implanting a prosthetic valve with the largest possible effective orifice area. The availability of transcatheter valve-in-valve replacement for failed bioprosthetic valves is already changing the dynamics of the Heart Team discussion regarding the trade-offs between mechanical and bioprosthetic valves.

Interventional Cardiology and Cardiovascular Surgery

Introduction

In patients with severe valvular heart disease, guideline-based surgical valve replacement or transcatheter implantation of a prosthetic heart valve is associated with improved survival and relief of symptoms. Prosthetic heart valves are designed to replicate the function of native valves by maintaining unidirectional blood flow and can be separated into two broad categories, mechanical and bioprosthetic (also called tissue) valves, each with different advantages and disadvantages.

This mini-series is divided into 4 parts:

Part 1 – Prosthetic valves: selection

Part 2 – Prosthetic valves: antithrombotic therapy

Part 3 – Prosthetic valves: imaging

Part 4 – Prosthetic valves: complications and dysfunction, pregnancy

Part 1 – Prosthetic valves: selection

History

In 1954 Hufnagel and colleagues [1] reported their successful treatment of aortic regurgitation by heterotopic implantation of a ball-valve prosthesis into the descending thoracic aorta. This novel concept in the therapy of heart valve disease set the stage for the development of a new disruptive technology that has caused a sea change. Since then, major advances in technology, surgery, and anaesthesia have made valve replacement a common procedure with relatively low mortality.

Mechanical heart valves

Mechanical heart valves (MHV) are made entirely from non-biological (artificial) materials including metals (titanium, cobalt), pyrolytic carbon, and polymers in order to provide mechanical stability and durability. Different types of MHV include caged ball valves such as the Starr-Edwards valve, tilting disc valves, e.g., the Björk-Shiley and Medtronic valves, and bileaflet valves such as the St. Jude Medical valve with various modifications on these designs. Caged ball valves are no longer implanted; bileaflet valves are the most common type used today. The primary components in this type are usually a fabric-covered sewing ring, stent, hinge, and 2 occluders (also called discs or leaflets) in order to be effective as a one-way valve.

The contemporary disc surfaces are characterised by improved blood biocompatibility and are somewhat resistant to thrombus formation. However, the lack of endothelial lining and blood stasis with the discs in closed position left mechanical valves at risk of thromboembolic complications. The major advantage of mechanical valves is their longevity; however, this benefit must be weighed against necessary lifelong anticoagulation with the combined risk of haemorrhage secondary to anticoagulation and thromboembolic complications in case of subtherapeutic anticoagulation.

The orientation of a bileaflet MHV influences intraventricular haemodynamics. An anti-anatomic orientation (the MHV hinge line oriented towards the left ventricular [LV] outflow tract and not parallel to the commissure line of the native valve) is associated with a more favourable LV flow pattern [2]. This MHV positioning redirects the LV inflow towards the LV outflow tract and may avoid unfavourable effects on LV energy kinetics and decrease the risk of thrombus formation (Figure 1).

Figure 1. Three-dimensional transoesophageal echocardiographic image of a mechanical bileaflet mitral valve, viewed en face from the left atrial side (surgical view) in diastole with the leaflets in the open position. Please note the anti-anatomical position of one lateral and one medial leaflet with the hinge line oriented towards the left ventricular outflow tract and not parallel to the mediolateral commissure line of the native valve.

Prosthetic heart valves: Part 1 – Selection (3)

Bioprosthetic valves

Bioprosthetic valves (BPV) are, at least in part, made from animal (e.g., porcine, bovine or equine) (heterograft or xenograft) or human (hom*ograft or allograft) tissue mounted onto a metal or polymer supporting structure with three pillars (also called struts or posts) and have a trileaflet configuration that resembles the geometry of a native aortic valve. While porcine aortic valves can be harvested whole with preservation of the natural leaflet attachments (valvar hinges), bovine or equine pericardial tissue has to be trimmed and fitted to a stent to mimic the functional architecture of valve leaflets.

Stentless valves have been introduced with the objective of improving haemodynamics, are essentially metal free and produce few, if any, ultrasound artefacts such as acoustic shadowing. Hence, their appearance on two-dimensional echocardiography and their flow dynamics are close to native valves. In order to decrease the immunogenicity and avoid a humoral or cellular immune system rejection when implanted in the human body, animal-derived valvular or non-valvular tissue valves are fixed in glutaraldehyde, a process that cross-links and masks the antigens and makes the tissue valve biocompatible [3]. Although BPV offer the advantage of avoiding lifetime anticoagulation, they are subject to structural valve degeneration, resulting in limited durability and exposing the patient to the risk of reintervention.

Transcatheter aortic valve implantation

The traditional treatment for severe symptomatic valve disease is surgical valve replacement or repair, utilising an open chest approach or minimally invasive surgery and cardiopulmonary bypass. With the advent of transcatheter aortic valve implantation (TAVI), there has been a paradigm shift in the management of patients with aortic valve stenosis in the last decade, with a rapid development of new devices and expansion to high, intermediate and even low surgical risk populations. As these patients are generally younger with a greater life expectancy, structural valve integrity becomes an important issue. Because TAVI is still a young technology compared to conventional surgical aortic valve replacement (SAVR), it will require several more years, possibly a decade, to demonstrate the same favorable long-term durability.

Compared to SAVR, TAVI shows a higher incidence of paravalvular regurgitation but a lower incidence of severe prosthesis-patient mismatch and lower transvalvular pressure gradients. The number of TAVI procedures has outnumbered aortic valve replacement by open heart surgery for treatment of symptomatic severe aortic stenosis in some countries. This percutaneous technique is now available across the entire surgical risk spectrum. In many patients, life expectancy may exceed transcatheter valve durability, and these patients may require a reintervention. A second TAVI within the first TAVI (so called TAV-in-TAV), which failed because of structural valve failure, is feasible and associated with a similar favourable outcome compared to TAVI for surgical aortic valve dysfunction [4].

Choice of prosthetic valves

The choice between a mechanical and a bioprosthetic valve is a complex decision based on prosthetic valve characteristics, patient-related factors (e.g., comorbidities) and patient preferences such as wishes and expectations. In general, all bioprosthetic valves are at risk of structural valve degeneration leading to a higher rate of reoperation; all mechanical valves require life-long anticoagulation to prevent thromboembolism, which is associated with a higher risk of bleeding. While structural valve degeneration increases with time and decreases with advanced age at the time of implantation, the risk of bleeding grows with increasing age [5]. Life expectancy for patients at the time of valve implantation is greater following aortic versus mitral valve replacement. Hence, patients after aortic valve replacement are more likely to experience clinically relevant BPV degeneration necessitating reintervention taking into account that not all BPV are alike in terms of durability.

A key attraction of BPV is the non-existing requirement for chronic anticoagulation, but the risks of bleeding and thromboembolism with mechanical prostheses are nowadays acceptable, especially in compliant patients with appropriate internationalised normalised ratio (INR) monitoring.

Therefore, the choice of valve depends heavily on the patients’ age, reflecting the time-dependent trade-off between risk of bleeding and need for reoperation. The recent institution of valve-specific U.S. guidelines, in accordance with the European guidelines but with different age limits regarding the selection of MHV versus BPV, takes into account the differences in outcome depending on the valve position [6]. Thus, the balance between valve durability versus risk of bleeding and thromboembolic events favours the choice of a mechanical valve in the aortic position in patients <50 years of age [7] and <60 years of age [8] who require an aortic valve replacement, unless anticoagulation is contraindicated, is not desired, or cannot be monitored (Figure 2). Both guidelines recommend a BPV in patients >65 years of age for aortic valve replacement. For middle-aged patients, both valve types are acceptable and, rather than setting arbitrary age limits, the choice should be individualised through a shared decision-making process with full discussion of the advantages and disadvantages. Anticoagulation with vitamin K antagonists (VKA) requires regular visits for monitoring of INR, point-of-care testing or self-testing (home monitoring) in connection with dietary restrictions, and may be hazardous in case of physical or occupational activities which may lead to accidents.

Finally, the personal perception of many patients regarding valve-related events such as bleeding or reoperation is emotionally charged. When a mitral valve repair is not possible, the age cut-off for implantation of an MHV is set at 65 years [7,8]. In addition to the patient and family, discussion by a Heart Team (consisting of a cardiologist, imaging specialist, cardiac surgeon, anaesthesiologist and others) may be helpful in some cases to take into account all available data and make a recommendation for the best choice and management of prosthetic valve complications after careful, comprehensive evaluation.

Depending on the institutional surgical expertise, the so-called Ross procedure (native pulmonary valve harvested and moved as an autograft to the aortic position combined with a hom*ograft placed in the pulmonary position) represents a relevant alternative in younger patients in whom anticoagulation is either contraindicated or undesired (Class IIb, level of evidence [LoE] B) [7]. The Ross procedure provides excellent valve haemodynamics without the need for anticoagulation. However, both the pulmonic hom*ograft and the neoaortic autograft are at risk of structural degeneration and failure, requiring reintervention at a later stage.

Figure 2. Societal recommendations for aortic and mitral prosthetic valve types according to patient age [7,8].

Prosthetic heart valves: Part 1 – Selection (4)

Reoperation for prosthetic valve dysfunction is usually associated with increased risk of morbidity and mortality when compared with the initial surgery due to advanced age and a higher comorbidity burden, particularly in patients undergoing urgent or emergency procedures. Although the in-hospital mortality rate has declined from more than 10% before the 1980s, it remains approximately 5% in contemporary surgery practice [9].

Several other factors should be considered. A mechanical prosthesis may be preferred for patients with another indication for permanent anticoagulation such as atrial fibrillation, high risk of repeat open heart surgery (e.g., porcelain aorta or those with prior radiation therapy) or a small aortic root size which precludes a future valve-in-valve procedure for a structurally failed aortic bioprosthesis. On the other hand, it may be prudent to choose a bioprosthetic valve even in patients who require anticoagulation for another indication with a simultaneous high bleeding risk requiring frequent interruptions for an extended period of time, which would place an MHV at serious risk of thromboembolism. Moreover, certain subgroups of patients, such as continuing drug abusers, in whom life expectancy is lower than the presumed durability of the bioprosthesis, may be candidates for a bioprosthetic valve irrespective of age. A bioprosthesis should also be considered in young women contemplating pregnancy, in whom a bioprosthetic valve is preferred, given the risks of anticoagulation and thromboembolism during pregnancy (Class IIa, LoE C) [10].

The mortality rate among dialysis patients remains high, especially after surgical valve replacement. The current societal guidelines have ceased to have explicit criteria for valve selection; this should be individualised to the patient [7,8]. Young patients without diabetes or New York Heart Association (NYHA) Class III or IV symptoms might survive long enough to justify placement of a mechanical valve, while a biological valve is suitable for most patients as the default option despite accelerated calcification and degeneration [11].

Following the TAVI trend, the ratio of surgically implanted BPV to MHV has been steadily increasing over recent decades [12], owing to a favourable haemodynamic profile, low thrombogenicity, and improvements in tissue processing intended to increase performance and durability. From a lifelong management perspective, a lower age threshold for implantation of BPV includes the consequence that not only will more patients need a reoperation in the future but also that that need will occur at a higher age with a negative impact on survival. The increasing use of BPV in younger patients may also be attributable to the availability of transcatheter valve-in-valve (VIV) implantation for failed aortic and mitral BPV as an acceptable alternative to redo surgery. Since new percutaneous therapies employed for native valve disease also have the potential to replace classic surgical reoperations in patients with deteriorated BPV, this option already has a profound impact on the dynamic discussion regarding the trade-offs between mechanical and bioprosthetic valves. However, transcatheter VIV implantation could also result in several adverse events including suboptimal haemodynamics with higher post-implantation gradients, coronary obstruction, and limited later access to coronary arteries [13].

Table 1. Factors to be considered for the choice of prosthetic heart valve.

In favour of a bioprosthesis

In favour of a mechanical valve

For AVR: age >65 years

For AVR: age <60/50 years

[7,8]

For MVR: age >70/65 years

[7,8]

For MVR: age <65 years

Anticoagulation contraindicated, not desired, or cannot be monitored

Other indication for anticoagulation (e.g., atrial fibrillation)

Desired pregnancy

Limited life expectancy

Small aortic root size (preclusion of future transcatheter valve-in-valve [VIV] implantation for failed aortic bioprosthesis)

Patient preference (avoidance of risk or inconvenience of anticoagulation)

Patient preference (avoidance of risk of reintervention)

Selection of valve prosthesis size

The term prosthesis-patient mismatch (PPM) was coined in 1978 by Rahimtoola [14] and describes the situation where the effective orifice area (EOA) in a normally functioning prosthetic valve is too small in relation to the patient’s body size to meet cardiac output requirements with incomplete relief of symptoms. The concept of relating the EOA to the body surface area in order to define PPM (severe <0.65 cm²/m², moderate 0.65–0.85 cm²/m² for aortic valves, and severe <0.9 cm²/m², moderate 0.9–1.2 cm²/m² for mitral valves) has become widely accepted [15,16]. However, indexation to body surface area may not be valid in obese patients; other indices based on the lean body mass or height may be more meaningful in this patient population. To overcome this limitation, it is thus recommended to use lower cut-off values of indexed EOA in patients with a body mass index ≥30 kg/m² (severe <0.55 cm²/m², moderate 0.55–0.70 cm²/m² for aortic valves, and severe <0.75 cm²/m², moderate 0.75–1.0 cm²/m² for mitral valves) [15]. PPM is a frequent cause of a high transprosthetic gradient immediately after valve implantation and should be suspected when the measured EOA is in accordance with the normal reference values in a valve with normal leaflet structure and mobility. In contrast to structural valve degeneration, abnormal valve haemodynamics are already present at the time of prosthesis implantation and there is no deterioration in haemodynamics over time.

Of note, prosthetic valve dysfunction (stenosis and/or regurgitation) and PPM may coexist. After aortic valve replacement, PPM is associated with worse haemodynamic performance and diminished cardiac reverse remodelling, leading to impaired functional capacity, accelerated structural valve degeneration (in bioprosthetic valves), and increased perioperative and overall mortality proportional to its severity [17]. Likewise, severe PPM after TAVI is associated with a higher mortality and heart failure hospitalisation rate at 1 year [18].

PPM following VIV implantation for failed aortic bioprosthetic valves could also negatively affect clinical and functional short- and long-term outcomes, specifically in patients with small (internal diameter ≤20 mm) compared to large failed bioprostheses and those with predominant valve stenosis as opposed to regurgitation [19,20]. A potential solution to avoid PPM with the VIV procedure would be to fracture the degenerated BPV preceding the new implantation, although not all BPV stents are breakable. In this context, it would be advisable to surgically implant a valve as large as possible and to avoid a small BPV with resultant PPM in order to preserve the option for a future VIV implantation.

Finally, no randomised controlled trials comparing this technique with redo surgery are available as yet. Nevertheless, this technology has recently been incorporated into the U.S. guidelines for patients with a high or prohibitive risk for redo surgery (Class IIa, LoE B) [7]. PPM after surgical mitral valve replacement has been less widely investigated. Despite some conflicting results, it appears that severe PPM is also an independent predictor of mortality after mitral valve replacement [21].

A prospective strategy to avoid or reduce the degree of PPM includes implantation of a prosthesis with a size as large as possible or a newer-generation prosthesis with superior haemodynamics. Occasionally, concomitant enlargement of the aortic annulus or root may be necessary, permitting implantation of a larger-sized prosthesis. This, however, adds complexity to the surgical procedure and possibly increases the operative risk. Most patients tolerate a mild degree of PPM. For symptomatic patients with severe PPM unresponsive to medical therapy and after exclusion of other causes of increased transprosthetic gradients, the only effective intervention is redo surgery with implantation of a larger prosthetic valve and/or annulus/root enlargement. This approach requires careful consideration of the potential benefits versus the risk of reoperation.

References


  1. Hufnagel CA, Harvey WP, Rabil PJ, McDermott TF. Surgical correction of aortic insufficiency. Surgery. 1954;35:673-83.
  2. Van Rijk-Zwikker GL, Delemarre BJ, Huysmans HA. The orientation of the bi-leaflet CarboMedics valve in the mitral position determines left ventricular spatial flow patterns. Eur J Cardiothorac Surg. 1996;10:513-20.
  3. Schoen FJ, Levy RJ. Calcification of tissue heart valve substitutes: progress toward understanding and prevention. Ann Thorac Surg. 2005;79:1072-80.
  4. Landes U, Sathananthan J, Witberg G, De Backer O, Sondergaard L, Abdel-Wahab M, Holzhey D, Kim WK, Hamm C, Buzzatti N, Montorfano M, Ludwig S, Conradi L, Seiffert M, Guerrero M, El Sabbagh A, Rodés-Cabau J, Guimaraes L, Codner P, Okuno T, Pilgrim T, Fiorina C, Colombo A, Mangieri A, Eltchaninoff H, Nombela-Franco L, Van Wiechen MPH, Van Mieghem NM, Tchétché D, Schoels WH, Kullmer M, Tamburino C, Sinning JM, Al-Kassou B, Perlman GY, Danenberg H, Ielasi A, Fraccaro C, Tarantini G, De Marco F, Redwood SR, Lisko JC, Babaliaros VC, Laine M, Nerla R, Castriota F, Finkelstein A, Loewenstein I, Eitan A, Jaffe R, Ruile P, Neumann FJ, Piazza N, Alosaimi H, Sievert H, Sievert K, Russo M, Andreas M, Bunc M, Latib A, Godfrey R, Hildick-Smith D, Chuang MA, Blanke P, Leipsic J, Wood DA, Nazif TM, Kodali S, Barbanti M, Kornowski R, Leon MB, Webb JG. Transcatheter replacement of transcatheter versus surgically implanted aortic valve bioprostheses. J Am Coll Cardiol. 2021;77:1-14.
  5. van Geldorp MWA, Jamieson WRE, Kappetein AP, Ye J, Fradet GJ, Eijkemans MJ, Grunkemeier GL, Bogers JJC, Takkenberg JJ. Patient outcome after aortic valve replacement with mechanical or biological prosthesis. Weighing lifetime anticoagulant related event risk against reoperation risk. J Thorac Cardiovasc Surg. 2009;137:881-6.
  6. Goldstone AB, Chiu P, Baiocchi M, Lingala B, Patrick WL, Fischbein MP, Woo YJ. Mechanical or biologic prostheses for aortic-valve and mitral-valve replacement. N Engl J Med. 2017;377:1847-57.
  7. Writing Committee Members, Otto CM, Nishimura RA, Bonow RO, Carabello BA, Erwin JP 3rd, Gentile F, Jneid H, Krieger EV, Mack M, McLoed C, O’Gara PT, Rigolin VH, Sundt TM 3rd, Thompson A, Toly C. 2020 ACC/AHA guideline for the management of patients with valvular heart disease: executive summary: a report of the American College of Cardiology/American Heart Association Joint Committee on Clinical Practice Guidelines. J Am Coll Cardiol. 2021;77:450-500.
  8. Baumgartner H, Falk V, Bax JJ, De Bonis M, Hamm C, Holm PJ, Iung B, Lancellotti P, Lansac E, Muñoz DR, Rosenhek R, Sjögren S, Tornos Mas P, Vahanian A, Walther T, Wendler O, Windecker S, Zamorano JL; ESC Scientific Document Group. 2017 ESC/EACTS Guidelines for the management of valvular heart disease. Eur Heart J. 2017;38:2739-91.
  9. Leontyev S, Borger MA, Davierwala P, Walther T, Lehmann S, Kempfert J, Mohr FW. Redo aortic valve surgery: early and late outcomes. Ann Thorac Surg. 2011;91:1120-6.
  10. Regitz-Zagrosek V, Roos-Hesselink JW, Bauersachs J, Blomström-Lundqvist C, Cífková R, De Bonis M, Iung B, Johnson MR, Kintscher U, Kranke P, Lang IM, Morais J, Pieper PG, Presbitero P, Price S, Rosano GMC, Seeland U, Simoncini T, Swan L, Warnes CA; ESC Scientific Document Group. 2018 ESC guidelines for the management of cardiovascular diseases during pregnancy. Eur Heart J. 2018;39:3165-241.
  11. Manghelli JL, Carter DI, Khiabani AJ, Gauthier JM, Moon MR, Munfakh NA, Damiano RJ, Corvera JS, Melby SJ. A 20-year multicenter analysis of dialysis-dependent patients who had aortic or mitral valve replacement: implications for valve selection. J Thorac Cardiovasc Surg. 2019;158:805-13.
  12. Iribarne A, Leavitt BJ, Robich MP, Sardella GL, Gelb DJ, Baribeau YR, McCullough JN, Weldner PW, Clough RA, Ross CS, Malenka DJ, DiScipio AW; Northern New England Cardiovascular Disease Study Group. Tissue versus mechanical aortic valve replacement in younger patients: a multicenter analysis. J Thorac Cardiovasc Surg. 2019;158:1529-38.
  13. Baumgartner H. Transcatheter valve-in-valve implantation in failed aortic bioprosthetic valves: a word of caution in times of euphoria. Eur Heart J. 2020;41:2743-6.
  14. Rahimtoola SH. The problem of valve prosthesis-patient mismatch. Circulation. 1978;58:20-4.
  15. Lancellotti P, Pibarot P, Chambers J, Edvardsen T, Delgado V, Dulgheru R, Pepi M, Cosyns B, Dweck MR, Garbi M, Magne J, Nieman K, Rosenhek R, Bernard A, Lowenstein J, Vieira ML, Rabischoffsky A, Vyhmeister RH, Zhou X, Zhang Y, Zamorano JL, Habib G. Recommendations for the imaging assessment of prosthetic heart valves: a report from the European Association of Cardiovascular Imaging endorsed by the Chinese Society of Echocardiography, the Inter-American Society of Echocardiography, and the Brazilian Department of Cardiovascular Imaging. Eur Heart J Cardiovasc Imaging. 2016;17:589-90.
  16. Zoghbi WA, Chambers JB, Dumesnil JG, Foster E, Gottdiener JS, Grayburn PA, Khandheria BK, Levine RA, Marx GR, Miller FA Jr, Nakatani S, Quiñones MA, Rakowski H, Rodriguez LL, Swaminathan M, Waggoner AD, Weissman NJ, Zabalgoitia M, American Society of Echocardiography's Guidelines and Standards Committee; Task Force on Prosthetic Valves; American College of Cardiology Cardiovascular Imaging Committee; Cardiac Imaging Committee of the American Heart Association; European Association of Echocardiography; European Society of Cardiology; Japanese Society of Echocardiography; Canadian Society of Echocardiography; American College of Cardiology Foundation; American Heart Association; European Association of Echocardiography; European Society of Cardiology; Japanese Society of Echocardiography; Canadian Society of Echocardiography. Recommendations for evaluation of prosthetic valves with echocardiography and Doppler ultrasound. J Am Soc Echocardiogr. 2009;22:975-1014.
  17. Dayan V, Vignolo G, Soca G, Paganini JJ, Brusich D, Pibarot P. Predictors and outcome of prosthesis-patient mismatch after aortic valve replacement. J Am Coll Cardiol Imaging. 2016;9:924-33.
  18. Herrmann HC, Daneshvar SA, Fonarow GC, Stebbins A, Vemulapalli S, Desai ND, Malenka DJ, Thourani VH, Rymer J, Kosinski AS. Prosthesis-patient mismatch in patients undergoing transcatheter aortic valve replacement: from the STS/ACC TVT Registry. J Am Coll Cardiol. 2018;72:2701-11.
  19. Bleiziffer S, Simonato M, Webb JG, Rodés-Cabau J, Pibarot P, Kornowski R, Windecker S, Erlebach M, Duncan A, Seiffert M, Unbehaun A, Frerker C, Conzelmann L, Wijeysundera H, Kim WK, Montorfano M, Latib A, Tchetche D, Allali A, Abdel-Wahab M, Orvin K, Stortecky S, Nissen H, Holzamer A, Urena M, Testa L, Agrifoglio M, Whisenant B, Sathananthan J, Napodano M, Landi A, Fiorina C, Zittermann A, Veulemans V, Sinning JM, Saia F, Brecker S, Presbitero P, De Backer O, Søndergaard L, Bruschi G, Nombela Franco L, Petronio AS, Barbanti M, Cerillo A, Spargias K, Schofer J, Cohen M, Muñoz-Garcia A, Finkelstein A, Adam M, Serra V, Teles RC, Champagnac D, Iadanza A, Chodor P, Eggebrecht H, Welsh R, Caixeta A, Salizzoni S, Dager A, Auffret V, Cheema A, Ubben T, Ancona M, Rudolph T, Gummert J, Tseng E, Noble S, Bunc M, Roberts D, Kass M, Gupta A, Leon MB, Dvir D. Long-term outcomes after transcatheter aortic valve implantation in failed bioprosthetic valves. Eur Heart J. 2020;41:2731-42.
  20. Dvir D, Webb JG, Bleiziffer S, Pasic M, Waksman R, Kodali S, Barbanti M, Latib A, Schaefer U, Rodés-Cabau J, Treede H, Piazza N, Hildick-Smith D, Himbert D, Walther T, Hengstenberg C, Nissen H, Bekeredjian R, Presbitero P, Ferrari E, Segev A, de Weger A, Windecker S, Moat NE, Napodano M, Wilbring M, Cerillo AG, Brecker S, Tchetche D, Lefèvre T, De Marco F, Fiorina C, Petronio AS, Teles RC, Testa L, Laborde JC, Leon MB, Kornowski R; Valve-in-Valve International Data Registry Investigators. Transcatheter aortic valve implantation in failed bioprosthetic valves. JAMA. 2014;312:162-70.
  21. Magne J, Mathieu P, Dumesnil JG, Tanneé D, Dagenais F, Doyle D, Pibarot P. Impact of prosthesis-patient mismatch on survival after mitral valve replacement. Circulation. 2007;115:1417-25.

Notes to editor


Authors:

Roland R. Brandt1, MD, FESC, FACC; Philippe Pibarot2, DMV, PhD, FAHA, FACC, FESC, FASE, FCCS

  1. Department of Cardiology, Kerckhoff Heart Center, Bad Nauheim, Germany;
  2. Institut Universitaire de Cardiologie et de Pneumologie de Québec/Québec Heart & Lung Institute, Laval University, Québec, QC, Canada

Address for correspondence:

Dr Roland R. Brandt, Department of Cardiology, Kerckhoff Heart Center, Benekestr. 2-8, 61231 Bad Nauheim, Germany

E-mail: r.brandt@kerckhoff-klinik.de

Author disclosures:

Prof. Philippe Pibarot has received funding from Edwards Lifesciences for echocardiography core laboratory analyses with no personal compensation.

Dr. Roland Brandt has no conflicts of interest to declare.

The content of this article reflects the personal opinion of the author/s and is not necessarily the official position of the European Society of Cardiology.

Prosthetic heart valves: Part 1 – Selection (2024)

FAQs

How many types of prosthetic heart valves are there? ›

Three basic types of mechanical valve design exist: bileaflet, monoleaflet, and caged ball valves (Figure 1A, 1B, and 1C).

What are the two types of prosthetic heart valve? ›

Surgical valve replacement is performed with mechanical or bioprosthetic valves. For most patients, a choice is made between a mechanical valve or a stented bioprosthesis [1,2]: Current mechanical options include bileaflet (eg, St.

What are prosthetic heart valves used for? ›

Artificial heart valves are used to replace heart valves that have become damaged with age or by certain diseases or congenital abnormalities.

Which heart valve is best? ›

Biological valve: Pros and cons

Typically, biological valves last between 10 and 15 years, so you may require another replacement surgery at some point. They don't come with a higher risk of blood clots, so you most likely won't need to take a blood thinner. Biological valves are best, Dr.

What is an example of a prosthetic valve? ›

Bioprosthetic valve

Porcine models include the Carpentier-Edwards valves (Edwards Lifesciences) and Hanco*ck II and Mosaic valves (Medtronic).

Which is the oldest prosthetic valve? ›

Hufnagel valve: the first prosthetic mechanical valve.

How long do prosthetic heart valves last? ›

They usually last 20 years or more. Other problems might happen with the valve, such as an infection. As long as you have the valve, you and your doctor will need to watch for signs of problems. After surgery, you may need to take the blood thinner called warfarin.

What is a prosthetic heart called? ›

A total artificial heart (TAH) is a pump that is placed in the chest to replace damaged heart ventricles and valves. (Ventricles pump blood to the lungs and other parts of the body.) Once the pump has been placed in the chest, a machine called a driver controls the pump outside the body.

Do prosthetic valves require anticoagulation? ›

Prosthetic valves require consideration for anticoagulation postoperatively to prevent thrombotic events. The traditional method of anticoagulation is warfarin which requires frequent blood test to check prothrombin (PT) time and International ratio (INR).

What are the 5 heart valves? ›

Overview. There are four valves in the heart: aortic valve, mitral valve, tricuspid valve, and pulmonary valve. The valves are designed to control the direction of blood flow through the heart.

Can you replace 3 heart valves? ›

Triple valve replacement (TVR) is a type of triple valve surgery and is challenging for most cardiac surgeons due to its prolonged periods of cardiopulmonary bypass (CPB) and aortic cross-clamping for the patients, who are commonly at late stages of RHD [5, 6].

What is it called when you only have 2 heart valves instead of 3? ›

A bicuspid aortic valve is an aortic valve that has two flaps (cusps) instead of three. It may cause a narrowed or obstructed aortic valve opening (aortic valve stenosis), making it difficult for the heart to pump blood into the body's main artery (aorta).

Can you replace all 4 heart valves? ›

Conclusions: Long-term management is challenging for patients who have experienced quadruple valve replacement with mechanical valves; however, promising results could mean that replacement of all 4 heart valves in 1 operation is feasible in patients with quadruple valve disease, and an INR of 1.5 to 2.0 could be ...

What is the most common heart valve replacement? ›

The aortic valve is the most common valve to be replaced. The mitral valve is the most common valve to be repaired. Only rarely is the tricuspid valve or the pulmonic valve repaired or replaced.

What is the most common heart valve? ›

Mitral valve prolapse: The most common heart valve abnormality and the No. 1 cause for mitral regurgitation, this is when the mitral valve doesn't open and close properly.

When are all 4 valves of the heart closed? ›

All Valves Closed

When the intraventricular pressures fall sufficiently at the end of phase 4, the aortic and pulmonic valves abruptly close (aortic precedes pulmonic) causing the second heart sound (S2) and the beginning of isovolumetric relaxation.

What are the 4 main functions of the heart? ›

It pumps blood throughout your body, controls your heart rate and maintains blood pressure. Your heart is a bit like a house. It has walls, rooms, doors, plumbing and an electrical system. All the parts of your heart work together to keep blood flowing and send nutrients to your other organs.

Do all heart valves have 3 cusps? ›

The cusps of the heart valves serve to seal the heart valves when closed. There are normally three cusps for each valve except the mitral valve (hence its alternate name, "bicuspid valve".) "Nodules" are located at the tip of the valve, to form a tighter seal.

What is the strongest valve in the heart? ›

The left ventricle is the largest and strongest chamber in your heart. The left ventricle's chamber walls are only about 1.0 to 1.3cm, but they have enough force to push blood through the aortic valve and into your body.

How do I choose a valve rating? ›

The right valve choice means matching the valve's size to expected flow through the system. Know the chemical compatibility requirements. The valve materials need to be compatible with the gases or liquids flowing through it. Plastic valves usually resist harsh or corrosive chemicals better than metal valves.

Which valve is better metal or tissue? ›

Compared to tissue valves, mechanical valves increase a patient's risk of blood clot formation as well as severe bleeding from the mandatory anti-clotting medication. As a result, tissue valves are often more suitable than mechanical valves for patients who have a high risk of clotting or bleeding.

What are the three types of prosthesis? ›

What Are the Four Types of Prosthetics?
  • Transradial. A transradial prosthesis is an artificial arm that attaches below the elbow. ...
  • Transhumeral. A transhumeral prosthesis is an artificial arm that connects to the body above the elbow but below the shoulder. ...
  • Transtibial. ...
  • Transfemoral. ...
  • Other prosthesis types.
24 May 2021

What are the four types of prosthetics? ›

There are many types of prosthetic devices to help people regain mobility. They fall into four main categories; transradial, transhumeral, transtibial, and transfemoral.

Can you hear a prosthetic heart valve? ›

Mechanical valves generate a clicking sound that is often audible to patients and even patients' relatives [7, 8]. However, cardiac surgeons may underestimate the impact of this continuous valve noise on patients' QOL, unlike life-threatening complications, including anticoagulation and thromboembolic events.

Who invented the prosthetic heart valve? ›

Developed by Dr. Charles Hufnagel in 1952, the first artificial heart valve, also known as the caged ball, represented the first long-term success in prosthetic heart valves that would in turn, come to shape modern medical practice around the use and development of artificial organs.

Who was the first in the world to prosthetic heart valve? ›

The first successful totally artificial device to replace a cardiac valve was implanted in the aortic-valve position by Dr. Dwight Harken in March 1960 at the Peter Bent Brigham Hospital in Boston.

Can artificial heart valves fail? ›

Bioprosthetic heart valves are often favored over more durable mechanical valves because of a lower risk of thrombotic and bleeding events and the desire to avoid anticoagulation. With time, bioprosthetic tissue can be expected to deteriorate and eventually fail.

Can you live 20 years after heart valve replacement? ›

In low-risk patients, median survival time ranged from 16.2 years in patients aged 60 to 64 years to 6.1 years in patients aged ≥85 years.

How many times can you replace your heart valve? ›

Two or 3 cardiac reoperations may be required after a 1st successful valvular surgery, due to complications that beset mechanical or bioprosthetic valves, such as degeneration.

What blood thinner can you take with an artificial heart valve? ›

Warfarin is the current standard for oral anticoagulation therapy in patients with mechanical heart valves, yet optimal therapy to maximize anticoagulation and minimize bleeding complications requires routine coagulation monitoring, possible dietary restrictions, and drug interaction monitoring.

Can a prosthetic heart valve be replaced? ›

Mechanical valve replacement

If your heart valve can't be repaired and a catheter-based procedure isn't an option, the valve might need to be replaced.

What are prosthetic valves made of? ›

Bioprosthetic valves are usually made from animal tissue (heterograft/xenograft) attached to a metal or polymer support. Bovine (cow) tissue is most commonly used, but some are made from porcine (pig) tissue. The tissue is treated to prevent rejection and calcification.

What is a prosthetic heart made of? ›

The heart is made out of flexible silicone and works with an external pump to push air and fluids through the heart. It currently cannot be implanted into humans, but it is a promising start for artificial hearts.

What is the disadvantage of a prosthetic valve? ›

The biggest drawback of a bioprosthetic heart valve is that it will inevitably degenerate over time and fail, therefore requiring repeat procedures in those who survive long enough to warrant it.

Do prosthetic valves cause blood clots? ›

Prosthetic heart valve thrombosis is a rare, but serious complication of a heart valve replacement procedure. A blood clot called a thrombus is attached to or near a prosthetic heart valve. This can obstruct blood flow or interfere with the function of the valve.

Is the most common complication of prosthetic valves? ›

Structural valve deterioration is a clinically important long-term complication of bioprosthetic valves, causing stenosis, regurgitation or a combination of both, ultimately necessitating reintervention.

What types of prosthetic heart valve are currently available for patients? ›

Bioprosthetic (xenograft) valves are made from porcine valves or bovine pericardium. Porcine models include the Carpentier-Edwards valves (Edwards Lifesciences) and Hanco*ck II and Mosaic valves (Medtronic).

How many heart valves are there? ›

A normal heart and heart valve problems

The four heart valves, which keep blood flowing in the right direction, are the mitral, tricuspid, pulmonary and aortic valves. Each valve has flaps (leaflets) that open and close once per heartbeat.

What is considered a prosthetic heart valve? ›

Prosthetic heart valves are designed to replicate the function of native valves by maintaining unidirectional blood flow and can be separated into two broad categories, mechanical and bioprosthetic (also called tissue) valves, each with different advantages and disadvantages.

Which heart valve is replaced the most? ›

The aortic valve is the most common valve to be replaced. The mitral valve is the most common valve to be repaired. Only rarely is the tricuspid valve or the pulmonic valve repaired or replaced.

How often do prosthetic heart valves need to be replaced? ›

Mechanical valves don't usually wear out. They usually last 20 years or more. Other problems might happen with the valve, such as an infection. As long as you have the valve, you and your doctor will need to watch for signs of problems.

Which is the most important valve in the heart? ›

The aortic valve is the final valve that oxygen-rich blood passes through before exiting the heart and coursing through the rest of the body. The valve prevents blood from flowing back to the left ventricle.

Can you only have 2 heart valves? ›

In bicuspid aortic valve, the valve has only 2 small parts (leaflets), instead of the normal 3. This condition can be present from birth (congenital). In some cases, a person can have 3 leaflets but 2 leaflets become fused together over time. This is a condition called functional bicuspid valve.

What is heart valve surgery called? ›

Transcatheter aortic valve replacement (TAVR) is a minimally invasive procedure to replace a narrowed aortic valve that fails to open properly (aortic valve stenosis). In this procedure, surgeons insert a catheter into the leg or chest and guide it to the heart.

Do prosthetic valves need anticoagulation? ›

Prosthetic valves require consideration for anticoagulation postoperatively to prevent thrombotic events. The traditional method of anticoagulation is warfarin which requires frequent blood test to check prothrombin (PT) time and International ratio (INR).

Is prosthetic heart valve same as mechanical? ›

Biologic prosthetic valves are associated with a higher risk of reoperation than mechanical valves because of structural valve deterioration, but mechanical valves typically necessitate lifelong anticoagulation, which increases the risk of hemorrhage and thromboembolism.

Top Articles
Latest Posts
Article information

Author: Tish Haag

Last Updated:

Views: 6026

Rating: 4.7 / 5 (67 voted)

Reviews: 82% of readers found this page helpful

Author information

Name: Tish Haag

Birthday: 1999-11-18

Address: 30256 Tara Expressway, Kutchburgh, VT 92892-0078

Phone: +4215847628708

Job: Internal Consulting Engineer

Hobby: Roller skating, Roller skating, Kayaking, Flying, Graffiti, Ghost hunting, scrapbook

Introduction: My name is Tish Haag, I am a excited, delightful, curious, beautiful, agreeable, enchanting, fancy person who loves writing and wants to share my knowledge and understanding with you.